0 false
false
false EN-ZA
X-NONE
X-NONE /* Style Definitions */
table.MsoNormalTable
{mso-style-name:”Table Normal”;
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:””;
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin-top:0cm;
mso-para-margin-right:0cm;
mso-para-margin-bottom:10.0pt;
mso-para-margin-left:0cm;
line-height:115%;
mso-pagination:widow-orphan;
font-size:11.0pt;
font-family:”Calibri”,”sans-serif”;
mso-ascii-font-family:Calibri;
mso-ascii-theme-font:minor-latin;
mso-hansi-font-family:Calibri;
mso-hansi-theme-font:minor-latin;
mso-fareast-language:EN-US;} Leading consulting engineering firm GIBB has been appointed as the engineering and construction monitoring contractor for the 20 km Kalagadi Manganese railway siding, connecting to the main manganese corridor from Hotazel in the Northern Cape to Port Elizabeth.
The railway siding will serve Kalagadi’s mine to export manganese ore (sinter) through the Port of Ngqura in the Eastern Cape. The railway line will also be used to import coke for the beneficiation process.
The railway siding consists of an electrified and signalled running line, with a balloon configuration of 12 km. Yard 1 comprises 3,4 km electrified lines and Yard 2 4.1 km of un-electrified lines.
The yard layout has a balloon shape for the rapid loading of the sinter product, a linear yard for the tippler off-loading of coke, a yard for shunting movements and a locomotive shed for light maintenance, according to Wimpie Oosthuizen, technical executive: rail at GIBB.
Oosthuizen commented that three design issues relating to the site conditions were solved by innovative use of material.
Due to the challenge of obtaining construction material, one of the pavement layers that required material from a commercial source was changed to utilise the abundant calcrete material.
The calcrete material was processed with 3% of cement to provide the same structural requirement as the imported material.
Oosthuizen explained the second design element: Kalahari sand is highly collapsible when loading is increased and water is added. The predicted subsidence was more than the allowable specification.
The design to mitigate the potential collapse/subsidence of the soils was to excavate the material by 500 mm, and wetting and compacting the on-site material with a three-sided impact roller.
The on-site material was then strengthened by placing a 500-mm-thick pioneer layer on top of the on-site material, which formed the foundation for the bulk fills.
The third design element was that the traction substation was changed from a traditional brick building to a containerised solution.
This provided a total off-site design, supply and assembly solution. The completed containerised substation will then require minor installation works on-site, and in its installation will realise cost-savings compared to the original planned substation.
One of the major challenges on the project was to find suitable construction material for the bulk earthworks (fills, pavement layer works and service road). The importing of calcrete material from the neighbouring mine and utilising discarded rock material from the mining activities solved the major challenge of obtaining good construction material.
The project will be completed by the first quarter of 2014.